The thickener can be equipped with special probes for different measuring fields. It is possible to measure the thickness of virtually any homogeneous material with this spesimeter. You can purchase a special sensor for materials with damping or dispersion properties, such as plastics or cast elements.
Measuring range
(depending on the probe):
P-E: Pulse-Echo Mode 0.65 ... 600 mm (steel)
E-E: Dual eco mode 2.50 ... 100 mm
Precision:
±0.04 mm H[mm] (<10 mm); ±0,4 % H[mm] (>10 mm)
H refers to the thickness of the material
Resolution:
0.1 mm / 0.01 mm / 0.001 mm (adjustable)
Measurable materials:
Metals
Plastic
Ceramics
Eposi resin
Crystal
and any homogeneous material
Measurement modes:
Pulse-echo (detection of faults and rechupes)
Double echo (hides coating thickness)
Calibration:
Ultrasound speed calibration
Zero point calibration
Two-point calibration
Display modes:
Normal mode, scan mode, differential mode
Units:
mm / inch
Data transmission:
Bluetooth / USB 2.0 printing
Memory:
Non-volatile for 100 data groups with 100 records each
Operating time:
Continuous operation 100 hours
Automatic stand-by mode (adjustable)
Auto shutdown mode (adjustable)
Feeding:
4 x 1.5V batteries, type AA
Screen:
320 x 240 pixel TFD LCD, color display with brightness adjustment
Operating conditions:
0 ... +50 °C, ≤80 % non-condensing R.H.
Storage conditions:
-20 ... +70 °C, ≤80 % non-condensing R.H.
Dimensions:
185 x 97 x 40 mm
Weight:
375 g
Available sensor specifications
NO2
Frequency:
2.5 MHz
Diameter:
14 mm
Rank:
3 ... 40 mm (steel)
3 ... 300 mm (steel)
Min. diameter and thickness of the tube:
Not suitable for curved materials
Description:
For materials with damping or dispersion properties (plastics, castings)
NO5
Frequency:
5 MHz
Diameter:
10 mm
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement
NO5 / 90°
Frequency:
5 MHz
Diameter:
10
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement
NO7
Frequency:
7 MHz
Diameter:
6 mm
Rank:
0,65 ... 200 mm (steel)
Min. diameter and thickness of the tube:
15 x 2 mm
Description:
For thin walls or heavily curved tubes
HT5
Frequency:
5 MHz
Diameter:
12 mm
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
30 mm
Description:
For high temperatures (max. 300 °C)
P5EE
Frequency:
5 MHz
Diameter:
10 mm
Rank:
P-E: 2 ... 600 mm, E-E: 2.5 ... 100 mm
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement and double echo
1 x PCE-TG 300 Thickness Meter
1 x P5EE Sensor
1 x Coupling gel, 100ml
1 x Carrying case
1 x Instruction Manual
4 x 1.5V batteries, type AA