Product description
The thickener can be equipped with special probes for different measuring fields. It is possible to measure the thickness of virtually any homogeneous material with this spesimeter. You can purchase a special sensor for materials with damping or dispersion properties, such as plastics or cast elements.
Measuring range
(depending on the probe):
P-E: Pulse-Echo Mode 0.65 ... 600 mm (steel)
E-E: Dual eco mode 2.50 ... 100 mm
Precision:
±0.04 mm H[mm] (<10 mm); ±0,4 % H[mm] (>10 mm)
H refers to the thickness of the material
Resolution:
0.1 mm / 0.01 mm / 0.001 mm (adjustable)
Measurable materials:
Metals
Plastic
Ceramics
Eposi resin
Crystal
and any homogeneous material
Measurement modes:
Pulse-echo (detection of faults and rechupes)
Double echo (hides coating thickness)
Calibration:
Ultrasound speed calibration
Zero point calibration
Two-point calibration
Display modes:
Normal mode, scan mode, differential mode
Units:
mm / inch
Data transmission:
Bluetooth / USB 2.0 printing
Memory:
Non-volatile for 100 data groups with 100 records each
Operating time:
Continuous operation 100 hours
Automatic stand-by mode (adjustable)
Auto shutdown mode (adjustable)
Feeding:
4 x 1.5V batteries, type AA
Screen:
320 x 240 pixel TFD LCD, color display with brightness adjustment
Operating conditions:
0 ... +50 °C, ≤80 % non-condensing R.H.
Storage conditions:
-20 ... +70 °C, ≤80 % non-condensing R.H.
Dimensions:
185 x 97 x 40 mm
Weight:
375 g
Available sensor specifications
NO2
Frequency:
2.5 MHz
Diameter:
14 mm
Rank:
3 ... 40 mm (steel)
3 ... 300 mm (steel)
Min. diameter and thickness of the tube:
Not suitable for curved materials
Description:
For materials with damping or dispersion properties (plastics, castings)
NO5
Frequency:
5 MHz
Diameter:
10 mm
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement
NO5 / 90°
Frequency:
5 MHz
Diameter:
10
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement
NO7
Frequency:
7 MHz
Diameter:
6 mm
Rank:
0,65 ... 200 mm (steel)
Min. diameter and thickness of the tube:
15 x 2 mm
Description:
For thin walls or heavily curved tubes
HT5
Frequency:
5 MHz
Diameter:
12 mm
Rank:
1 ... 600 mm (steel)
Min. diameter and thickness of the tube:
30 mm
Description:
For high temperatures (max. 300 °C)
P5EE
Frequency:
5 MHz
Diameter:
10 mm
Rank:
P-E: 2 ... 600 mm, E-E: 2.5 ... 100 mm
Min. diameter and thickness of the tube:
20 x 3 mm
Description:
Normal measurement and double echo
1 x PCE-TG 300 Thickness Meter
1 x P5EE Sensor
1 x Coupling gel, 100ml
1 x Carrying case
1 x Instruction Manual
4 x 1.5V batteries, type AA